December 27, 1996
Mr. James Thewis, VP of Operations Bests FoodService, Inc. 8900 Miramar Place San Diego, CA 92121
Subject: Environmental Audit Report
Dear Mr. Thewis:
Attached is the report of the Environmental Review conducted at your location on November 22, 1996. Please note that you have also been provided with a summary sheet of recommendations on a table at the end of the report. This table is used to track and report your follow-up to the recommendations listed in the attached report. Please send this form, once completed, to Mr. Ted Starks, Senior Project Manager within the Real Estate and Construction section of Bests FoodService Inc., Ten Parkway North, Northfield, IL 60015. Mr. Starks can be reached at (847) 205 8815.
If there are any questions concerning this report, please let Ted or myself know. Please thank your staff on-site for their assistance during this audit.
Sincerely,
John R. Wiemhoff, CHMM, REM. REA, CEA, Environmental Technical Director
An environmental audit was conducted at the San Diego, CA Bests FoodService site by John Wiemhoff on November 22, 1996. During this audit, an opening meeting was held with the following site personnel: Mr. Jim Thewis, VP of Operations and Mr. Nik Norris, Facility Engineering Manager/Environmental Coordinator. The opening meeting was followed by a review of the plant layout print, followed by a brief plant tour. Following the tour, key personnel were interviewed, and site environmental compliance and project files were reviewed.
Site environmental areas with program areas complete were the following: CFC management; facility management organization; secondary containment for aboveground tanks.
Areas in which the site is encouraged to address further are: replace or upgrade UST; No PCB determinations, continued stormwater permit documentation.
BESTS FOODSERVICE, INC.
AUDIT DATE: November 22, 1996; LOCATION: San Diego, CA; AUDITOR: J.R. Wiemhoff
ENVIRONMENTAL COMPLIANCE PROGRAM AUDIT; SCORING SUMMARY
AUDIT SECTION POSS. SCORE ACT. SCORE
I Facility Environmental Management Systems 35 35
II SARA Title III/Community Right-to-Know 35 30
III Chemical Emergency Planning and SPCC Plans 50 40
IV Used Oil Management 20 10
V Polychlorinated Biphenyls (PCBs) 10 0
VIA Water Supply 20 15
VIB Municipal Sanitary Wastewater Discharge 15 0
VIC NPDES Wastewater 5 5
VIC Stormwater 25 15
VIIA Underground Storage Tanks 25 5
VIIB Aboveground Storage Tanks 25 25
VIII Air Pollution Control 10 10
IX Asbestos 10 10
X Hazardous Waste 15 7
Total 300 207